Description
areas. The strong increase in demand for low-loss cables, which meet all the relevant requirements with regard to flame retardancy and low emissions in the event of fire, led to the development of the Ecoflex cables with Heatex jacket. Ecoflex cables with Heatex sheaths are flame retardant and have a low fire propagation. Heatex coats are low in smoke, the escape routes remain visible in case of fire. Heatex coats are halogen-free and contain no reactive elements such as fluorine, chlorine and bromine. They do not produce corrosive gases which can lead to high property damage. By contrast, standard coaxial cables with a PVC sheath are not halogen-free and therefore can not be used in hazardous areas. Critical to PVC cables is also the possible transmission of the flames in case of fire – a danger that exclude Ecoflex Heatex cables safely. The UV stability of the durable Heatex jacket also allows unrestricted outdoor use.
Ecoflex 10 Plus Heatex has a 7-core hybrid core conductor with aluminium core and welded copper sheath. The surface finish and the corresponding HF properties are significantly better than those of conventional copper strands. Another advantage is the double shielding: an overlapping copper foil and an overlying copper braid ensure a high shielding factor of > 90 dB at 1 GHz. With the fire protection rating Cca Ecoflex 10 Plus Heatex is approved for installation in public buildings. Ecoflex 10 Plus Heatex is certified for railway applications for interior and exterior use according to requirement sets R15 and R16 of the EN45545-2 standard.
Specifications
Diameter | 10.2 ± 0.2 mm |
Impedance | 50 ± 2 Ω |
Attenuation at 1 GHz / 100 m | 13.49 dB |
f max | 8 GHz |
Euroclass acc. to EN 50575 | Cca |
Properties
Certified according to EN 45545-2:2013+A1:2015 and EN 45545-2:2020 requirement sets R15 + R16 for railway applications
Flame retardancy tested according to EN 60332-1-2:2004 + A1:2015 + A11:2016 and EN 60332-1-3:2004 + A1:2015
Smoke density tested according to DIN EN 61034-2:2005
Smoke toxicity tested according to EN 50305:2002 Section 9.2
Vertical flame propagation tested according to EN 50305:2002 Section 9.1.1. (for cables with 12 mm > ⌀ > 6 mm)
Halogen-free tested according to DIN EN 50306-1:2003
Halogen acid gas content tested according to DIN EN 60754-1:2015 (HCI < 0,5%)
Acidity of gases tested according to DIN EN 60754-2:2015 (pH value > 4,3)
Conductivity of gases tested according DIN EN 60754-2:2015 (< 10,0 µS/mm)
Fluorine content tested according to EN 60684-2:2011 Clause 45.2 Procedure A (< 0,1%)
Jacket material according to DIN EN 50290-2-27 (HD 624.7)
RoHS compliant (Directive 2011/65/EC & 2015/863/EU RoHS 3)
Fire retardant, low smoke, halogen free (LSZH)
UV-resistant